Third Party ECat report on Arxiv

Arxiv – Indication of anomalous heat energy production in a reactor device containing hydrogen loaded nickel powder

Giuseppe Levi, Bologna University, Bologna, Italy

Evelyn Foschi, Bologna, Italy

Torbjörn Hartman, Bo Höistad, Roland Pettersson and Lars Tegnér Uppsala University, Uppsala, Sweden

Hanno Essén, Royal Institute of Technology, Stockholm, Sweden

An experimental investigation of possible anomalous heat production in a special type of reactor tube named E-Cat HT is carried out. The reactor tube is charged with a small amount of hydrogen loaded nickel powder plus some additives. The reaction is primarily initiated by heat from resistor coils inside the reactor tube. Measurement of the produced heat was performed with high-resolution thermal imaging cameras, recording data every second from the hot reactor tube. The measurements of electrical power input were performed with a large bandwidth threephase power analyzer. Data were collected in two experimental runs lasting 96 and 116 hours, respectively. An anomalous heat production was indicated in both experiments. The 116-hour experiment also included a calibration of the experimental set-up without the active charge present in the E-Cat HT. In this case, no extra heat was generated beyond the expected heat from the electric input.

Computed volumetric and gravimetric energy densities were found to be far above those of any known chemical source. Even by the most conservative assumptions as to the errors in the measurements, the result is still one order of magnitude greater than conventional energy sources.

The device subject to testing was powered by 360 W for a total of 96 hours, and produced in all 2034 Watts thermal. This value was reached by calculating the power transferred by the E-Cat HT to the environment by convection and power irradiated by the device. The resultant values of generated power density (7093 W/kg) and thermal energy density (6,81 · 10^5 Watt hours per kg) place the E-Cat HT above conventional power sources.

Conclusions

The two test measurements described in this text were conducted with the same methodology on two different devices: a first prototype , termed E-Cat HT, and a second one, resulting from technological improvements on the first, termed E-Cat HT2 . Both have indicated heat production from an unknown reaction primed by heat from resistor coils.

The results obtained indicate that energy was produced in decidedly higher quantities than what may be gained from any conventional source. In the March test, about 62 net kWh were produced, with a consumption of about 33 kWh, a power density of about 5.3 · 10^5 , and a density of thermal energy of about 6.1 · 10^7 Wh/kg. In the December test, about 160 net kWh were produced, with a consumption of 35 kWh, a power density of about 7 · 10^3 W/kg and a thermal energy density of about 6.8 · 10^5 Wh/kg.

The difference in results between the two tests may be seen in the overestimation of the weight of
the charge in the first test (which was comprehensive of the weight of the two metal caps sealing the cylinder), and in the manufacturer’s choice of keeping temperatures under control in the second experiment to enhance the stability of the operating cycle.

In any event, the results obtained place both devices several orders of magnitude outside the bounds of the Ragone plot region for chemical sources.

Even from the standpoint of a “blind” evaluation of volumetric energy density, if we consider the whole volume of the reactor core and the most conservative figures on energy production , we still get a value of (7.93 ± 0.8) 10^2 MJ/ Liter that is one order of magnitude higher than any conventional source.

Lastly, it must be remarked that both tests were terminated by a deliberate shut down of the reactor, not by fuel exhaustion; thus, the energy densities that were measured should be considered as lower limits of real values.

If you liked this article, please give it a quick review on ycombinator or StumbleUpon. Thanks